AVENTICS CD12 Series 5/2-directional valve Technical Data

Technical data for the AVENTICS CD12 Series 5/2-directional valve, including working pressure, flow rate, connections, and electrical specifications.


AVENTICS CD12 Series 5/2-directional valve Technical Data - cover page
Brand
Aventics
Category
Automation control Equipment
Document type
Product Leaflet
Language
English
Pages
7
File format
PDF
File size
498 KB
Published
23 November, 2026
Updated
23 November, 2026
MD5 checksum
0C879C6F5FDDCAF26802639D6A8F8349

About this manual

The AVENTICS CD12 Series is a 5/2-directional spool valve with positive overlapping and soft sealing. It is electrically activated and has a nominal flow of 4100 l/min with G 1/2 compressed air connections.

Variants are available with internal or external pilot control and single solenoid operation. Working pressure ranges from 2 to 16 bar depending on part number, and coils are offered for 24 V DC or 110 V and 230 V AC.

What's inside

  • Technical data
  • Dimensions
  • Technical information
  • Material
  • Reverse polarity protection
  • ATEX
  • Weight
  • Operational voltage
  • Power consumption
  • Ambient temperature

Specifications

Nominal flow Qn4100 l/min
Compressed air connection outputG 1/2
Electrical connectionPlug, EN 175301-803, form A, 3-pin
Manual overridewith detent, without detent
Sealing principleSoft sealing
Duty cycle100 %
Max. particle size50 µm
Oil content of compressed air0 ... 1 mg/m³
Working pressure min./max.2 ... 10 bar
Reverse polarity protectionProtected against polarity reversal

Frequently asked questions

What is the nominal flow of the AVENTICS CD12 valve?

The nominal flow Qn is 4100 l/min.

What compressed air connection does the valve use?

It uses a G 1/2 compressed air connection.

What electrical connection is used?

A plug conforming to EN 175301-803, form A, 3-pin is used.

Is the valve protected against reverse polarity?

Yes, it is protected against polarity reversal.

Download PDF (498 KB)