Technical specifications and configuration options for the AVENTICS Series 581 configurable valve system.
This document details the AVENTICS Series 581 valve system, including its operating conditions, standards, and available variants. It provides technical specifications such as working pressure, ambient temperature, and medium compatibility. The system supports multiple configurations with different pilot valve widths and connection types, including manual override and electronic connections. Dimensions and port layouts are specified for various versions.
| Working Pressure | -0.95 ... 10 bar |
|---|---|
| Ambient Temperature | -10 ... 50 °C |
| Medium | Compressed air |
| Max. Particle Size | 50 µm |
| Oil Content | 0 ... 5 mg/m³ |
| Nominal Flow | 1100 l/min |
| Protection Class | IP65 or IP67 |
The maximum working pressure is 10 bar.
The ambient temperature range is -10 to 50 °C.
The system is designed for compressed air.
The maximum particle size is 50 µm.