Installation instructions for large format mineral fiber and fiberglass ceiling panels in 9/16" or 15/16" suspension systems, covering design…
This document provides installation requirements for large format mineral fiber and fiberglass ceiling panels installed in 9/16" or 15/16" suspension systems. It applies to panels with square lay-in or tegular edge details and addresses specific considerations for panels equal to or greater than 5 feet in length to ensure system integrity.
| Applicable Suspension Systems | 9/16" or 15/16" |
|---|---|
| Panel Thickness (Stabilizer Clip 435) | 3/4" to 1" |
| Panel Thickness (Stabilizer Clip 436) | 1-1/2" to 1-3/4" |
| Minimum Clearance for 2' Wide Panels | 3" |
| Minimum Clearance for 4' Wide Panels | 8" |
Stabilizer Clips are required when the length of grid between lateral supports is greater than 5'.
Two Stabilizer Clips must be installed at one-third points of the panel.
Armstrong SuperCoat Ceiling Panel Touch-up Paint is recommended for exposed cut edges.