Analog Devices TMP35/TMP36/TMP37 Temperature Sensor Data Sheet

Analog Devices TMP35/TMP36/TMP37 data sheet for low voltage Celsius temperature sensors with linear voltage output, accuracy, and application information.


Analog Devices TMP35/TMP36/TMP37 Temperature Sensor Data Sheet - cover page
Brand
Analog Devices
Category
Temperature sensors
Document type
Datasheet
Language
English
Pages
20
File format
PDF
File size
361 KB
Published
23 November, 2026
Updated
23 November, 2026
MD5 checksum
4026E976E8BF7E5D6AA4871EA0AF30D8

About this manual

The Analog Devices TMP35/TMP36/TMP37 data sheet describes low voltage, precision centigrade temperature sensors. They provide a voltage output linearly proportional to Celsius temperature and do not require external calibration for typical accuracies of ±1°C at +25°C and ±2°C over −40°C to +125°C.

The document includes specifications, pin configurations, typical performance characteristics, functional description, applications information, outline dimensions, and an ordering guide. It also covers shutdown operation, mounting considerations, basic temperature sensor connections, Fahrenheit thermometers, remote locations, long cables, and capacitive loads.

What's inside

  • Features
  • Applications
  • General Description
  • Pin Configurations
  • Specifications
  • Absolute Maximum Ratings
  • Typical Performance Characteristics
  • Functional Description
  • Applications Information
  • Outline Dimensions

Specifications

Supply voltage2.7 V to 5.5 V
Output scale factor10 mV/°C; 20 mV/°C on TMP37
Accuracy over temperature±2°C typical
Linearity±0.5°C typical
Temperature range−40°C to +125°C specified; operation to +150°C
Quiescent currentLess than 50 μA
Shutdown current0.5 μA max
Capacitive load stabilityStable with large capacitive loads
Package options3-lead TO-92, 8-lead SOIC_N, and 5-lead SOT-23

Frequently asked questions

What kind of output do the TMP35, TMP36, and TMP37 provide?

They provide a voltage output linearly proportional to Celsius (centigrade) temperature.

Do the TMP35, TMP36, and TMP37 need external calibration?

No. The data sheet says they do not require external calibration for typical accuracies of ±1°C at +25°C and ±2°C over −40°C to +125°C.

What are the output scale factors for TMP35/TMP36/TMP37?

The data sheet lists a 10 mV/°C scale factor, with 20 mV/°C on TMP37.

What packages are available for TMP35/TMP36/TMP37?

They are available in 3-lead TO-92, 8-lead SOIC_N, and 5-lead SOT-23 packages.

Download PDF (361 KB)