The Analog Devices MAX16126/MAX16127 load-dump/reverse-voltage protection circuits protect power supplies from overvoltage, reverse-voltage, and…
The MAX16126/MAX16127 are load-dump/reverse-voltage protection circuits that protect power supplies from damaging input voltage conditions, including overvoltage, reverse-voltage, and high-voltage transient pulses. Using a built-in charge pump, the devices control two external back-to-back n-channel MOSFETs that turn off and isolate downstream power supplies during damaging input conditions such as an automotive load-dump pulse or a reverse-battery condition.
The MAX16127 provides limiter-mode fault management for overvoltage and thermal shutdown conditions, while the MAX16126 provides switch-mode fault management. The devices operate from 3V to 30V with a protection range of -36V to +90V and are available in a 12-pin TQFN package over the automotive temperature range of -40°C to +125°C.
| Input Voltage Range | 3 to 30 V operating; -36 to +90 V protection |
|---|---|
| Package | 12-pin TQFN |
| Operating Temperature Range | -40°C to +125°C |
| Supply Current | 350µA max at 30V input |
| Shutdown Current | 100µA max at 30V input |
| Thermal Shutdown | +145°C |
| FLAG Output | Active-low |
The MAX16127 provides limiter-mode fault management for overvoltage and thermal shutdown conditions, while the MAX16126 provides switch-mode fault management.
The devices operate over the automotive temperature range of -40°C to +125°C.
The devices are available in a 12-pin TQFN package.