Analog Devices DC2879A LTM4660 High Density Hybrid Step-Down Synchronous Converter Demo Manual

Analog Devices DC2879A demo board uses the LTM4660 high density hybrid step-down converter to deliver 12V/25A from 36V to 60V.


Analog Devices DC2879A LTM4660 High Density Hybrid Step-Down Synchronous Converter Demo Manual - cover page
Brand
Analog Devices
Category
DC/DC Converter
Document type
User Manual
Language
English
Pages
10
File format
PDF
File size
750 KB
Published
17 November, 2026
Updated
17 November, 2026
MD5 checksum
5B22DE604CEF816F40DE1B329ACB1B59

About this manual

Analog Devices DC2879A is a demonstration circuit for the LTM4660 high density hybrid step-down synchronous converter. The board is specified for a 36V to 60V input, up to 65V during transients, and a 12V/25A output. The text states that the LTM4660 combines a soft-switching switched capacitor topology with a traditional step-down converter.

The document contains a quick start procedure, a performance summary, efficiency and output ripple plots, a load step figure, a thermal performance figure, and a parts list. It also includes notes on ripple measurement, the onboard dynamic load circuit, removing R3 before applying external voltage to EXTVCC, and increased switching frequency after long running.

What's inside

  • Description
  • Board Photo
  • Quick Start Procedure
  • Performance Summary
  • Efficiency vs Load Current
  • Output Voltage Ripple
  • Load Step
  • Thermal Performance
  • Parts List

Specifications

Input voltage range36 V to 60 V
Output voltage (VOUT)12 V
Maximum output current25 A
Typical efficiency96.6% at VIN = 48V, VOUT = 12V, IOUT = 25A
Peak efficiency97.0% at VIN = 48V, VOUT = 12V
Default switching frequency at startup430 kHz

Frequently asked questions

What input voltage range does the DC2879A demo board accept?

The input voltage range is 36 V to 60 V.

What output can the DC2879A demo board deliver?

It can deliver 12 V at 25 A.

What is the default switching frequency at startup?

The default switching frequency at startup is 430 kHz.

What is the typical efficiency at 48 V input and 25 A load?

The typical efficiency is 96.6% at VIN = 48V, VOUT = 12V, and IOUT = 25A.