Explains why isolation is used in VFD and power supply designs and lists Analog Devices isolation products and architectures.
This Analog Devices application introduction (project code APM_ISO_VFD_2015) discusses isolation in variable frequency drive and power supply applications. It covers reasons for isolation, including reducing noise interference, handling voltage level differences, device interconnection, and safety and insulation.
The document also describes isolated system architectures and Analog Devices isolation technologies and products, including iCoupler digital isolators, isolated sensing devices, and isolated IGBT/MOSFET gate drivers.
| iCoupler polyimide working voltage | 400 V rms for 50 years |
|---|---|
| iCoupler surge rating | greater than 6 kV |
| ADuM14x isolation rating | 3.75 kV rms |
| AD7403 maximum working voltage | 830 V rms |
| AD7401A maximum working voltage | 630 V rms |
| ADuM4135 working voltage | 500 V rms, 1200 V dc |
| ADuM4223 high-side and low-side isolation | 537 V peak and 800 V peak |
It is used to reduce noise interference, handle voltage level differences, protect interconnected devices, and provide safety and insulation.
A two isolation barriers design, or connecting power and control circuits to the same ground.
iCoupler digital isolators, isolated sensing, and isolated IGBT/MOSFET gate drivers.
IEC61800-5-1, IEC62040-1-1, IEC 60747-5-5, VDE 0884-10, and UL1577.