Analog Devices ADXL312 3-Axis Digital Accelerometer Data Sheet

This datasheet details the ADXL312, a low-power 3-axis digital accelerometer with selectable ranges up to ±12 g, supporting SPI and I2C interfaces.


Analog Devices ADXL312 3-Axis Digital Accelerometer Data Sheet - cover page
Brand
Analog Devices
Category
sensor
Document type
Datasheet
Language
English
Pages
29
File format
PDF
File size
1 MB
Published
13 October, 2026
Updated
13 October, 2026
Model
ADXL312
MD5 checksum
162AC4AF5F2F072272369E53834A77CF

About this manual

The ADXL312 is a small, thin, low-power 3-axis digital accelerometer designed for high-resolution measurements up to ±12 g. It features a selectable measurement range of ±1.5 g, ±3 g, ±6 g, or ±12 g and provides a fixed 10-bit resolution, which can increase to 13-bit resolution at the ±12 g range. The device supports both SPI (3- and 4-wire) and I2C digital interfaces and includes embedded FIFO technology to minimize host processor load. It is well-suited for applications such as car alarms, hill start aids, and data recorders.

What's inside

  • Features
  • Applications
  • Specifications
  • Absolute Maximum Ratings
  • Pin Configuration
  • Serial Communications
  • FIFO
  • Self-Test
  • Register Map
  • Outline Dimensions

Specifications

Measurement Range±1.5, 3, 6, 12 g
Operating Temperature Range-40°C to +105°C
Supply Voltage Range2.0 V to 3.6 V
Supply Current (Data rate > 100 Hz)100 µA to 300 µA
Supply Current (Standby Mode)0.1 µA to 2 µA
Output Resolution10 to 13 bits
Package Type32-lead LFCSP
Shock Survival10,000 g

Frequently asked questions

What are the selectable measurement ranges for the ADXL312?

The device supports user-selectable measurement ranges of ±1.5 g, ±3 g, ±6 g, or ±12 g.

Which digital interfaces does the ADXL312 support?

The ADXL312 supports SPI (3- and 4-wire) and I2C digital interfaces.

What is the maximum operating temperature range?

The device operates over a wide temperature range from -40°C to +105°C.

What is the typical supply current in measurement mode at 100 Hz?

The supply current is typically between 100 µA and 170 µA at a data rate greater than 100 Hz.