Analog Devices AD8676 Dual Rail-to-Rail Output Op Amp Data Sheet

The Analog Devices AD8676 is a dual ultraprecision operational amplifier with 2.8 nV/√Hz voltage noise, rail-to-rail output swing, and 12 μV typical offset…


Analog Devices AD8676 Dual Rail-to-Rail Output Op Amp Data Sheet - cover page
Brand
Analog Devices
Category
amplifier
Document type
Datasheet
Language
English
Pages
13
File format
PDF
File size
349 KB
Published
25 November, 2026
Updated
25 November, 2026
Model
AD8676
MD5 checksum
04A7DF094C5E320B5237C5EA000C963F

About this manual

The Analog Devices AD8676 is a dual ultraprecision operational amplifier offering ultralow offset, drift, and voltage noise combined with very low input bias currents over the full operating temperature range. It features rail-to-rail output swings, very low noise, and operation from ±5 V to ±18 V.

The device is specified for the extended industrial temperature range (−40°C to +125°C) and is available in 8-lead MSOP and 8-lead narrow SOIC packages. Typical applications include precision instrumentation, PLL filters, laser diode control loops, strain gage amplifiers, medical instrumentation, and thermocouple amplifiers.

What's inside

  • Features
  • Applications
  • Pin Configurations
  • General Description
  • Revision History
  • Specifications
  • Electrical Specifications
  • Absolute Maximum Ratings
  • Thermal Resistance
  • Power Sequencing

Specifications

Voltage noise density at 1 kHz2.8 nV/√Hz
Offset voltage typical12 μV
Input bias current maximum2 nA
Input offset drift maximum0.6 μV/°C
Open-loop gain120 dB
Gain bandwidth product10 MHz
Supply voltage range±5 V to ±18 V
Operating temperature range−40°C to +125°C

Frequently asked questions

What is the voltage noise density of the AD8676 at 1 kHz?

The voltage noise density is 2.8 nV/√Hz at 1 kHz.

What packages are available for the AD8676?

The AD8676 is available in the 8-lead MSOP and the 8-lead narrow SOIC packages.

What is the operating temperature range of the AD8676?

The AD8676 operates over the extended industrial temperature range of −40°C to +125°C.