Analog Devices AD22105 Low Voltage Resistor Programmable Thermostatic Switch Datasheet

This datasheet describes the AD22105, a single-supply solid-state thermostatic switch with user-programmable temperature setpoints from -40°C to +150°C.


Analog Devices AD22105 Low Voltage Resistor Programmable Thermostatic Switch Datasheet - cover page
Brand
Analog Devices
Category
Other Electronics
Document type
Datasheet
Language
English
Pages
9
File format
PDF
File size
351 KB
Published
11 November, 2026
Updated
11 November, 2026
Model
AD22105
MD5 checksum
16CAA48021D7EB9B6372B56F1DDE5FD1

About this manual

The AD22105 is a single-supply semiconductor thermostat switch that integrates a temperature sensor, setpoint comparator, and open-collector output stage. It requires only one external programming resistor to set the switching temperature accurately within a wide operating range of -40°C to +150°C. The device features a unique circuit architecture that minimizes self-heating errors and includes an optional internal 200 kΩ pull-up resistor for driving light loads like CMOS inputs or low-power LEDs.

Key specifications include a setpoint accuracy of ±2.0°C and a preset hysteresis of 4.08°C to prevent rapid thermal cycling. The device operates on a supply voltage ranging from +2.7 V to +7.0 V, making it suitable for battery-powered applications. It is designed for use in industrial process control, thermal management systems, CPU monitoring, and fan control circuits.

What's inside

  • Features
  • Applications
  • Functional Block Diagram
  • Specifications
  • Absolute Maximum Ratings
  • Ordering Guide
  • Pin Configuration
  • Typical Performance Characteristics
  • Setpoint Resistor Calculation
  • Effect of Resistor Tolerance

Specifications

Supply Voltage Range+2.7 V to +7.0 V
Operating Temperature Range-40°C to +150°C
Setpoint Accuracy±2.0°C
Preset Hysteresis4.08°C
Power Dissipation230 mW @ 3.3 V
Internal Pull-up Resistor200 kΩ
Output Low Voltage250 mV
Supply Current (Output LOW)120 µA
Supply Current (Output HIGH)90 µA

Frequently asked questions

What is the operating temperature range of the AD22105?

The device operates in a wide temperature range from -40°C to +150°C.

How is the setpoint temperature programmed?

The setpoint is programmed using a single external resistor connected between the RSET pin and GND.

What is the typical hysteresis value?

The device has approximately 4°C of hysteresis to prevent rapid thermal on/off cycling.

Can the AD22105 drive an LED directly?

Yes, it can drive a low power LED indicator directly due to its internal pull-up resistor.