The RIK-5A Rogowski Integrator Kit is a plug-and-play retrofit solution for power meters or equipment with a 5A current input. It includes a three-channel integrator unit with seven configurable CT ratios per channel, three Rogowski coils (16" to 47"), and a 24Vdc power supply. The kit measures current from 2.5A to 60,000A at 50/60Hz and can be surface-mounted or DIN-rail mounted.

The manual covers safety information, hardware overview with dimensions, installation wiring for coil inputs and 5A outputs, configuration via DIP switches for each channel's current range, and measurement specifications. An appendix lists key specifications including accuracy, burden, frequency range, and operating temperature.

What's inside

  • Safety Information
  • Overview
  • What's Included
  • Hardware Overview
  • Dimensions
  • Installation
  • Configuration
  • Measurements
  • Appendix: Key Specifications

Specifications

Current Measurement Range2.5A - 60000A
Output Current0-6ARMS (0-5ARMS Nominal)
Sensing Range500A, 1000A, 2500A, 5000A, 10000A, 25000A and 50000A (user selectable)
Maximum Burden1.8VA per channel
Maximum Output Impedance50mΩ
Measurement Channels3 (three-phase or single-phase)
Frequency45Hz to 65Hz
Accuracy±1% Full Scale Error
Channel Cross Talk<-60dB
Maximum Operating Temperature55°C (131°F)

Frequently asked questions

What current ranges can the RIK-5A measure?

The RIK-5A can measure from 2.5A to 60,000A with user-selectable ranges of 500A, 1000A, 2500A, 5000A, 10000A, 25000A, and 50000A.

How is the RIK-5A powered?

The RIK-5A requires 24Vdc power, supplied by a 100-240Vac (50/60Hz) adapter that connects to the 'L' and 'N' terminals.

What is the output current of the RIK-5A?

The integrator outputs 0-6ARMS with a nominal 5ARMS at rated current.

How many measurement channels does the RIK-5A have?

The RIK-5A has three measurement channels for three-phase or single-phase applications.