A&D AD-4430A DIN Rail Weighing Module Simplified Instruction Manual

Simplified instruction manual for the A&D AD-4430A DIN rail weighing module featuring analog 4-20mA output.


A&D AD-4430A DIN Rail Weighing Module Simplified Instruction Manual - cover page
Brand
AD
Category
Other device
Document type
User Manual
Language
English
Pages
2
File format
PDF
File size
502 KB
Published
17 November, 2026
Updated
17 November, 2026
MD5 checksum
5B5BE2F2A428CBE0FCCE8CB6727D895D

About this manual

The A&D AD-4430A is a DIN rail weighing module designed to measure micro-volt output from load cells and convert it into mass. It features a 5-digit 7-segment monitor and supports analog (4-20mA) output, control I/O, and USB connectivity for function settings.

The module supports the connection of up to four load cells and includes functions for zero calibration, span calibration, and digital linearization to compensate for non-linearity between the zero point and weighing capacity.

What's inside

  • Cautions
  • General Specifications
  • Panels
  • Status Indicator LED Description
  • Keys Operation Mode
  • Calibration
  • Span Calibration using Mass
  • Digital Linearization
  • Calibration Errors

Specifications

Voltage requirementDC 24 V +10%, -15%
Power requirement6 W Max.
Load cell power supplyDC 5 V 350 Ω sensor
Operating conditions-10 °C to + 50 °C, Max 85 %RH (no condensation)

Frequently asked questions

How many load cells can be connected to the AD-4430A?

Up to 4 load cells can be connected to the module.

What is the operating temperature range for the module?

The operating temperature is between -10°C and +50°C (14°F to 122°F).

What is the purpose of digital linearization?

It is a non-linearity compensation function used to rectify or reduce linearity deviation between the zero point and weighing capacity.