The ifm electronic PP755X operating instructions describe a pressure sensor that monitors system pressure in a plant. The unit measures relative pressure and is suited for use in mobile vehicles. It generates output signals according to the parameter settings and provides process data via IO-Link, with communication also possible through the ifm handheld programming unit PP2001.
The document covers safety instructions, functions and features, operating modes, pressure monitoring and switching functions, and the teach function. It also explains installation, electrical connection, parameter setting, operation, technical data, setting ranges for the set points, and factory settings.
| Pressure type | Relative pressure |
|---|---|
| Maximum application pressure for gaseous media | 25 bar |
| Recommended tightening torque | 25 Nm (max. 50 Nm) |
| Voltage supply for communication mode | 18...32 V |
| Electrical supply standard | EN 50178, SELV, PELV |
The document states that the unit is suited for use in mobile vehicles. It monitors the system pressure in a plant.
The PP755X measures relative pressure.
For gaseous media, the application is limited to a maximum of 25 bar.
The recommended tightening torque is 25 Nm, with a maximum of 50 Nm.