This document is the user manual for ATV71L elevator dedicated inverter, software version V2.6. The document describes the features and dimensions of the product, and provides wiring diagrams and installation recommendations.
The manual describes the software functions and operating procedures for the Schneider ATV71L elevator private‑frequency transformer. It includes installation steps, configuration parameters, and safety information required for proper use.
Technical data such as input voltage ranges, EMC compliance, and power ratings are listed, along with reference to relevant IEC/EN standards. The document also contains troubleshooting tips and contact information for Schneider Electric support.
| Input voltage (low range) | 200–240 V, 50/60 Hz |
|---|---|
| Input voltage (high range) | 380–480 V, 50/60 Hz |
| EMC standard (general) | IEC/EN 61800-3 |
| EMC standard (immunity) | IEC/EN 61000-4-2 |
The ATV71L can operate on 200–240 V or 380–480 V, both at 50/60 Hz.
The device complies with IEC/EN 61800‑3 and IEC/EN 61000‑4‑2 among other EMC standards.