UT602/UT603 User Manual is a user manual for UT602 Inductance Tester and UT603 Inductance Capacitance Tester, which details the product's performance features, operating methods, safety operating rules, etc.
The UNI-T UT602 inductance meter and UT603 inductance capacitance meter are handheld 3 1/2-digit manual-range digital instruments built around large-scale integrated circuits and a dual-integration A/D converter. They measure resistance, transistor hFE, diode forward voltage drop, circuit continuity, and capacitance/inductance, with data hold available only on the UT602.
The manual includes safety rules, electrical symbols, general specifications, appearance and button functions, display symbols, operating instructions, technical specifications, battery and fuse replacement, and maintenance guidance. This manual is written in Chinese.
| Range selection | Manual |
|---|---|
| Maximum display | 1999 |
| Internal battery | 9V alkaline battery |
| Fuse for L/C terminals | φ5×20-F 0.315A/250V |
| Operating temperature | 0℃∽40℃ |
| Dimensions | 172mm×83mm×38mm |
| Weight | Approx. 310g including battery |
It uses an internal 9V alkaline battery.
Yes, data hold display is provided only on the UT602 model.
Remove the test leads, switch off the power, open the battery cover, and install a new 9V battery.
The fuse is φ5×20-F 0.315A/250V.