SKF EAZ 80/130 & EAZ 130/170 Adjustable Electromagnetic Induction Heater User Manual

The SKF EAZ 80/130 and EAZ 130/170 adjustable electromagnetic induction heaters are used to remove inner rings of various sizes of cylindrical roller bearings with inner diameters of 80 to 130 mm and 130 to 170 mm, when the fit with the shaft is up to grade n6.


Brand
SKF
Category
Industrial Supply
Document type
User Manual
Language
Chinese
Pages
9
File format
PDF
File size
311 KB
Updated
30 September, 2023
MD5 checksum
4856BFAD4D0B1D4BE470E266E76CDFD1

About this manual

The SKF EAZ series are adjustable electromagnetic induction heaters designed for removing inner rings of cylindrical roller bearings. The heater uses a ring‑shaped magnetic yoke with six adjustable magnetic poles, each equipped with an induction coil that generates a 50/60 Hz alternating magnetic field to heat and expand the bearing inner ring for easy removal. Two size ranges are offered: EAZ 80/130 for inner‑ring diameters 80‑130 mm and EAZ 130/170 for 130‑170 mm.

The manual outlines safety requirements, such as proper grounding, keeping a 5 m exclusion zone around the heater for people with pacemakers or metal objects, and ensuring only qualified personnel perform installation and maintenance. Operating steps include connecting the power cable by a certified electrician, adjusting the magnetic yoke to fit the bearing, activating the heater, and monitoring temperature with a precise thermometer. The device features automatic over‑temperature protection and a remote control for convenient operation. This manual is written in Chinese.

What's inside

  • Safety Instructions
  • Introduction
  • Applications
  • Technical Parameters
  • Operating Instructions
  • EU Declaration of Conformity

Specifications

Power cable plug typeDIN 49463
Weight (EAZ 80/130)28 kg
Power supply option (EAZ 80/130A)2 × 230 V / 50 Hz, 45 A
Power supply option (EAZ 130/170D)3 × 230 V / 50 Hz, 43 A

Frequently asked questions

How should the power cable be connected to the heater?

The power cable must be connected to the supply cabinet by a qualified electrical engineer, matching the voltage shown on the heater, and the plug must be securely attached to the cable connector while ensuring the machine is properly grounded.

What happens if the induction coil temperature becomes too high?

The heater automatically shuts off and an alarm lamp lights to indicate over‑temperature, after which the unit can be used again once it cools down.

Can the heater be used near people with pacemakers?

No. The manual requires keeping a distance of at least 5 m from anyone with a pacemaker or metal objects in their body while the heater is operating.