This manual covers the installation and operation of SKF’s Machine Condition Transmitters (MCT) models CMSS530(A) and CMSS590(A). These devices convert vibration signals into 4-20 mA outputs for integration with PLCs or DCS systems. The CMSS530 is a velocity transmitter, while the CMSS590 is an enveloped acceleration transmitter. Both can be ordered with or without a monitor module for alarm functionality.

The manual includes sections on powering the device, transducer connections, output configuration, alarm settings, and general severity guidelines for vibration measurements. It also provides technical details on filters, pin assignments, and troubleshooting.

What's inside

  • The MCT Transmitter
  • Installing the Machine Condition Transmitter
  • Setting Monitor Alarms
  • Interfacing the MCT with Other Monitoring Systems
  • General Severity Level Guidelines
  • Vibration Enveloped Acceleration Measurements

Specifications

Output Signal4-20 mA current proportional to vibration level
Transmitter ModelsCMSS530 (velocity) and CMSS590 (enveloped acceleration)
Sensor CompatibilityLow-impedance accelerometer or velocity sensor

Frequently asked questions

What are the two main models of the MCT transmitter?

The two main models are CMSS530, a 4-20 mA velocity transmitter, and CMSS590, an enveloped acceleration transmitter.

What is the output of the MCT transmitter?

The output is a 4-20 mA current proportional to the vibration level, within a specified full range such as 0-1 IPS RMS for velocity or 0-10 gE for enveloped acceleration.

Can the MCT be used with other monitoring systems?

Yes, the MCT can be interfaced with other monitoring systems via its BNC connector and 4-20 mA output, suitable for PLCs or DCS systems.