This manual introduces the functions, features, installation, configuration and usage of COMWAY WG-8010 GPRS DTU for users' reference.


Brand
Comway
Document type
User Manual
Language
Chinese
Pages
20
File format
PDF
File size
850 KB
Updated
01 October, 2023
MD5 checksum
A2EF158886E7C7E4A67C5DAF6869F405

About this manual

The WG-8010 GPRS DTU is an industrial‑grade device with a built‑in GPRS module and RS‑232/485/422 interfaces for connecting RTUs, PLCs, and industrial PCs. It supports multiple communication modes, including transparent data transfer, ID‑based transmission, and various remote wake‑up methods such as SMS, phone call, and local serial data.

The manual covers mechanical installation, antenna and SIM card mounting, power supply requirements, and detailed configuration using AT commands or the modem‑config software. It also explains status LED indications, reliability mechanisms, and remote management features. This manual is written in Chinese.

What's inside

  • Product Introduction
  • Features
  • Technical Specifications
  • Ordering Model Numbers
  • Installation
  • AT Command Configuration
  • Modem‑Config Software Setup
  • Network Transmission Protocols
  • SMS Function Configuration
  • Remote Wake‑up Methods

Specifications

GSM/GPRS frequency bands850/1900 or 900/1800 MHz
GPRS multi‑slot classClass 10
GPRS terminal device classClass B
SIM card count1
Serial interface standardRS‑232/485/422
Input voltage5 V – 16 V DC
Weight130 g
Dimensions108 × 65 × 26 mm
Operating temperature-30 °C to 70 °C
ESD protection15 kV
Surge protection2 kV

Frequently asked questions

What are the default serial port settings for the DTU?

Baud rate 115200, 8 data bits, no parity, 1 stop bit, and no hardware flow control.