This manual introduces the VS5000 series digital oscilloscope, covering safety precautions, system requirements, and an overview of the instrument’s features and performance. It explains the basic and advanced operation procedures, including menu navigation, channel setup, triggering, and measurement functions.
The document also contains detailed technical specifications, troubleshooting guidance, maintenance instructions, and contact information for service and support. It is intended for qualified users and service personnel who need to operate or maintain the VS5000 oscilloscope safely and effectively. This manual is written in Chinese.
| Analog channel bandwidth | 200 MHz (VS5202, VS5202D), 100 MHz (VS5102, VS5102D), 60 MHz (VS5062, VS5062D), 40 MHz (VS5042, VS5042D), 25 MHz (VS5022, VD5022D) |
|---|---|
| Real‑time sampling rate | 400 MSa/s (single channel) |
| Equivalent sampling rate | 25 GSa/s |
| Input impedance | 1 MΩ ± 2 % in parallel with 15 pF ± 3 pF (50 Ω ± 2 % option) |
| Maximum input voltage | 400 V DC + AC peak (1 MΩ input) |
| Power consumption | < 15 W |
| Operating temperature range | 10 °C ~ +40 °C |
| Weight | 0.7 kg (without packaging), 1.6 kg (with packaging) |
| IP protection rating | IP2X |
| Recommended calibration interval | 1 year |
The instrument can safely handle up to 400 V DC + AC peak when the input is connected to a 1 MΩ input impedance.
Rigol recommends calibrating the VS5000 series oscilloscope once a year.