This manual introduces the installation of the ISC2 seal.
This manual provides safety guidelines and preparation steps for installing Flowserve ISC2 mechanical seals. It emphasizes the use of protective equipment, compliance with MSDS information, and verification of seal dimensions before work begins.
The document details the installation procedure, required tools, torque specifications, and recommended pipe‑cleaning solutions. It also includes instructions for disassembly, repair, and re‑assembly to ensure reliable seal performance. This manual is written in Japanese.
| Seal face verticality tolerance | 0.0005 in (0.013 mm) |
|---|---|
| Maximum housing lateral movement | 0.010 in (0.25 mm) |
Follow the safety regulations, wear the specified protective equipment, and consult the MSDS for hazardous material handling.
A straight‑wrench, a torque wrench matching the bolt size, and a special extraction tool are required.
Use the recommended pipe‑cleaning solutions and follow the described flushing procedures before re‑assembly.