Dell PowerVault MD3460/3860i/3860f Storage Arrays Getting Started Guide Regulatory Model: E08J Series Regulatory Type: E08J001
This guide covers initial installation and configuration of Dell PowerVault MD3460/3860i/3860f storage arrays, including unpacking and racking the system, opening and closing disk drawers, installing physical disks, connecting and securing power cables, turning on the system, and installing the bezel.
It also lists related documents, technical assistance information, and technical specifications such as power, physical dimensions, weight, environmental limits, vibration, shock, altitude, and particulate contamination requirements.
| AC power supply wattage (per power supply) | 1,755 W |
|---|---|
| Heat dissipation (maximum) | 5988 BTU/hr |
| AC power voltage | 220 V AC, autoranging, 50 Hz/60 Hz |
| Battery | 6.6 V DC, 1100 mAh, 7.26 W Lithium Ion Battery |
| Height | 177.80 mm (7.0 inch) |
| Width | 482.60 mm (19.0 inch) with rack latches |
| Depth | 825.50 mm (32.5 inch) without bezel and handle |
| Weight (maximum configuration) | 105.20 kg (232.0 lb) |
| Weight (empty) | 19.50 kg (43.0 lb) |
| Maximum temperature gradient (operating and storage) | 20 °C/hour (36 °F/hour) |
| Storage temperature limits | -40 °C to 65 °C (-40 °F to 149 °F) |
| Continuous operation temperature range (altitude less than 950 m or 3117 ft) | 10 °C to 35 °C (50 °F to 95 °F) with no direct sunlight on the equipment |
| Operating humidity range | 10% to 80% Relative Humidity with 26 °C (78.8 °F) maximum dew point |
| Storage relative humidity | 5% to 95% RH with 33 °C (91 °F) maximum dew point |
| Operating vibration | 0.26 G rms at 5 Hz to 350 Hz in operational orientation |
| Storage vibration | 1.88 G rms at 10 Hz to 500 Hz for 15 minutes (all six sides tested) |
| Operating shock | One shock pulse in the positive z axis (one pulse on each side of the system) of 31 G for 2.6 m in the operational orientation |
| Storage shock | Six consecutively executed shock pulses in the positive and negative x, y, and z axes (one pulse on each side of the system) of 71 G for up to 2 m |
| Operating altitude | –30.5 m to 3048 m (–50 to 10,000 ft) |
| Storage altitude | Up to 12,000 m (39,370 ft) |
| Data center air filtration | ISO Class 8 per ISO 14644-1 with a 95% upper confidence limit |
| Data center air filtration (MERV) | MERV11 or MERV13 filtration |
| Copper coupon corrosion rate | <300 Å/month per Class G1 as defined by ANSI/ISA71.04-1985 |
| Silver coupon corrosion rate | <200 Å/month as defined by AHSRAE TC9.9 |
A minimum of three service technicians are required for safe installation of an empty system.
The empty weight is 19.50 kg (43.0 lb).
Each disk drawer must have a minimum of four physical disks installed starting from slots 0, 3, 6, and 9.
The Owner's Manual is available online at dell.com/support/manuals.