Dell PowerVault MD3460/3860i/3860f Storage Arrays Getting Started Guide

Dell PowerVault MD3460/3860i/3860f Storage Arrays Getting Started Guide Regulatory Model: E08J Series Regulatory Type: E08J001


Dell PowerVault MD3460/3860i/3860f Storage Arrays Getting Started Guide - cover page
Brand
DELL
Category
Storage
Document type
Quick Start Guide
Language
English
Pages
10
File format
PDF
File size
813 KB
Published
25 November, 2023
Updated
25 November, 2023
MD5 checksum
3F09C11BA95C691732E5F371A72D92B6

About this manual

This guide covers initial installation and configuration of Dell PowerVault MD3460/3860i/3860f storage arrays, including unpacking and racking the system, opening and closing disk drawers, installing physical disks, connecting and securing power cables, turning on the system, and installing the bezel.

It also lists related documents, technical assistance information, and technical specifications such as power, physical dimensions, weight, environmental limits, vibration, shock, altitude, and particulate contamination requirements.

What's inside

  • Installation and Configuration
  • Unpacking A Rack System
  • Opening And Closing The Disk Drawer
  • Installing The Physical Disks
  • Connecting The Power Cable(s)
  • Securing The Power Cable(s)
  • Turning On The System
  • Installing The Bezel
  • Other Information You May Need
  • Technical Specifications

Specifications

AC power supply wattage (per power supply)1,755 W
Heat dissipation (maximum)5988 BTU/hr
AC power voltage220 V AC, autoranging, 50 Hz/60 Hz
Battery6.6 V DC, 1100 mAh, 7.26 W Lithium Ion Battery
Height177.80 mm (7.0 inch)
Width482.60 mm (19.0 inch) with rack latches
Depth825.50 mm (32.5 inch) without bezel and handle
Weight (maximum configuration)105.20 kg (232.0 lb)
Weight (empty)19.50 kg (43.0 lb)
Maximum temperature gradient (operating and storage)20 °C/hour (36 °F/hour)
Storage temperature limits-40 °C to 65 °C (-40 °F to 149 °F)
Continuous operation temperature range (altitude less than 950 m or 3117 ft)10 °C to 35 °C (50 °F to 95 °F) with no direct sunlight on the equipment
Operating humidity range10% to 80% Relative Humidity with 26 °C (78.8 °F) maximum dew point
Storage relative humidity5% to 95% RH with 33 °C (91 °F) maximum dew point
Operating vibration0.26 G rms at 5 Hz to 350 Hz in operational orientation
Storage vibration1.88 G rms at 10 Hz to 500 Hz for 15 minutes (all six sides tested)
Operating shockOne shock pulse in the positive z axis (one pulse on each side of the system) of 31 G for 2.6 m in the operational orientation
Storage shockSix consecutively executed shock pulses in the positive and negative x, y, and z axes (one pulse on each side of the system) of 71 G for up to 2 m
Operating altitude–30.5 m to 3048 m (–50 to 10,000 ft)
Storage altitudeUp to 12,000 m (39,370 ft)
Data center air filtrationISO Class 8 per ISO 14644-1 with a 95% upper confidence limit
Data center air filtration (MERV)MERV11 or MERV13 filtration
Copper coupon corrosion rate<300 Å/month per Class G1 as defined by ANSI/ISA71.04-1985
Silver coupon corrosion rate<200 Å/month as defined by AHSRAE TC9.9

Frequently asked questions

How many service technicians are required to install an empty system?

A minimum of three service technicians are required for safe installation of an empty system.

What is the empty weight of the system?

The empty weight is 19.50 kg (43.0 lb).

How many physical disks must each disk drawer have at minimum?

Each disk drawer must have a minimum of four physical disks installed starting from slots 0, 3, 6, and 9.

Where is the Owner's Manual available?

The Owner's Manual is available online at dell.com/support/manuals.