Dell Storage Center SC400, SC420, and SC420F Expansion Enclosure Getting Started Guide
This is the Getting Started Guide (Guide de mise en route) for the Dell Storage Center SC400, SC420 and SC420F expansion enclosures, regulatory models E03J and E04J. It explains how to unpack the enclosure, install it in a rack, attach the front bezel and connect the power cables, and lists related documentation such as the Owner's Manual and the Dell Storage Manager Administrator Guide.
The guide also provides technical specifications for the SC400 series, including supported SAS hard drives and SSDs, enclosure management modules, rear-panel SAS connectors, power supplies, physical dimensions and weights, and environmental operating conditions for temperature, humidity and altitude. This manual is written in French.
| SC400 drives | Up to 12 hot-swappable 3.5-inch SAS drives or SSDs (12.0 Gbit/s) |
|---|---|
| SC420 drives | Up to 24 hot-swappable 2.5-inch SAS drives or SSDs (12.0 Gbit/s) |
| SC420F drives | Up to 24 hot-swappable 2.5-inch SAS SSDs (12.0 Gbit/s) |
| Enclosure management modules | Two hot-swappable EMM I/O modules |
| RAID controller | Two hot-swappable storage controllers |
| SAS connectors | Four mini-SAS HD connectors per EMM, SFF-8086/SFF-8088 compliant |
| Power supply | 600 W, 100–240 VAC auto-selecting, 50/60 Hz |
| Thermal dissipation | 2,047 BTU/h |
| Height | 8.7 cm (3.43 in) |
| Width | 48.2 cm (18.98 in) |
| Depth | SC400: 59.4 cm; SC420/SC420F: 54.1 cm |
| Maximum weight | SC400: 28.59 kg; SC420/SC420F: 24.2 kg |
| Operating temperature | SC400: 5–35 °C; SC420/SC420F: 10–35 °C |
| Storage temperature | -40 °C to 65 °C |
| Operating relative humidity | 8% to 85% non-condensing |
| Operating altitude | -16 m to 3,048 m (-50 to 10,000 ft) |
The SC400 supports up to 12 hot-swappable 3.5-inch SAS hard drives or SSDs at 12.0 Gbit/s, and also supports self-encrypting drives (SED).
Make sure the enclosure power switches are OFF, connect the cables to the power supply blocks, secure them with the retention straps, then plug the other end into a grounded outlet or a separate source such as a UPS or power distribution unit.
The SC420 and SC420F operate from 10 °C to 35 °C (50 °F to 95 °F) with a maximum temperature increase of 10 °C (18 °F) per hour.