This document describes the Coriolis flowmeter kits used with Graco ProMix® 2KS/2KE/3KS proportioners, Informer® Fluid Monitoring Kits, and ProControl™ 1KS/1KE Management Kits for Fluid and Air, in non-IS systems.
This manual provides instructions and parts information for Graco 313599S Coriolis meter kits, including Endress+Hauser Promass and Cubemass meters, for use with Graco ProMix 2KS/2KE/3KS proportioners, Informer kits, and ProControl 1KS/1KE management kits in non-IS systems.
It covers installation, hazardous location and intrinsically safe requirements, fluid supply, mounting, cable connections, operation, start-up, pressure relief, and technical data such as maximum working pressure of 2300 psi (16 MPa, 160 bar).
| Maximum Working Pressure | 2300 psi (16 MPa, 160 bar) |
|---|---|
| Metering Tube Size | 1/8 in. (3 mm) |
| Bare Meter Hazardous Location Approval | Class I, Div I, Group C and D |
| Intrinsic Safety Rating | Class I, Div I, Group D, T3 |
They are for use with Graco ProMix 2KS/2KE/3KS proportioners, Informer Fluid Monitoring Kits, and ProControl 1KS/1KE Management Kits for Fluid and Air in non-IS systems.
The maximum working pressure is 2300 psi (16 MPa, 160 bar).
Yes, bare meters are approved for use in explosive atmospheres if all installation requirements are met.