The Dell MD1280 Data Storage Enclosure Getting Started Guide provides information on how to install and configure the Dell MD1280 Data Storage Enclosure.
This guide explains how to install and set up the Dell MD1280 data storage enclosure. It covers rack safety requirements, unpacking, mounting the enclosure, installing disk drives, and connecting and securing power cables.
The document also lists technical specifications for drives, I/O modules, connectivity, RAID and management support, power supplies, dimensions, weight, and environmental requirements. This manual is written in Portuguese.
| Drive support | Up to 84 3.5-inch SAS hard drives with hot swap (6.0 Gbps or 12.0 Gbps) |
|---|---|
| I/O modules | Two hot-swappable EMM I/O modules |
| Enclosure chain capacity | Up to 168 hard drives in enclosure chains with redundant path |
| RAID management | Dell Storage System Manager version 6.4 or later |
| Power supply rating | 2.8 kW, 200 to 240 VAC (8.6 A to 4.3 A) |
| Maximum configured weight | 130.7 kg (287.5 lb) |
| Height | 22.23 cm (8.75 in) |
| Width | 48.26 cm (19 in) |
| Depth | 91.5 cm (36 in) from mounting bracket to rear surface |
| Operating temperature | 5°C to 35°C (41°F to 95°F) |
| Operating relative humidity | 20% to 80% non-condensing |
| Operating altitude | -30.5 m to 3,000 m (-100 ft to 10,000 ft) |
| Rack space required | 5U space at the bottom of a 20U rack |
The enclosure supports up to 84 3.5-inch SAS hard drives with hot swap at 6.0 Gbps or 12.0 Gbps.
The installation site needs 208 V from an independent source or a rack PDU with a UPS; a 110 V power supply will not work.
Load the rack from the bottom up for weight stability, and do not remove more than one enclosure at a time.
The maximum operating temperature is 35°C, and the rack design must account for this limit.