Technical specifications of Dell EMC PowerEdge R750xd/R750xa.
The document provides the legally required technical specifications for the Dell PowerEdge R730 and R730xd systems. It lists power ratings for 1100 W, 750 W, and 495 W power supplies, the 3 V CR2032 system battery, and a maximum operating ambient temperature of 35°C, with notes on higher-temperature Dell Fresh Air configurations.
It also includes the Getting Started With Your System heading and a Quick Resource Locator link (dell.com/QRL/Server/PER730) for videos, documentation, and troubleshooting information. The specifications are repeated in several languages, including English, Chinese, Japanese, Korean, and Indonesian.
| IT power system phase-to-phase voltage | Not exceeding 230 V |
|---|---|
| 1100 W (Platinum) AC power rating | 100–240 V AC, 50/60 Hz, 12 A–6.5 A |
| 1100 W (Platinum) DC power rating | -(48–60) V DC, 32 A |
| 750 W (Platinum) AC power rating | 100–240 V AC, 50/60 Hz, 10 A–5 A |
| 750 W (Titanium) AC power rating | 200–240 V AC, 50/60 Hz, 5 A |
| 750 W (Platinum) AC/DC power rating (China only) | 100–240 V AC, 50/60 Hz, 10 A–5 A or 240 V DC |
| 495 W (Platinum) AC power rating | 100–240 V AC, 50/60 Hz, 6.5 A–3 A |
| System battery | 3 V CR2032 lithium coin cell |
| Maximum operation ambient temperature | 35°C |
| Dell Fresh Air validated temperature | Up to 45°C and humidity up to 90 percent (29°C maximum dew point) |
The document lists 1100 W Platinum, 750 W Platinum, 750 W Titanium, and 495 W Platinum power supplies, with AC and DC input ratings.
The system uses a 3 V CR2032 lithium coin cell battery.
The maximum operating ambient temperature is 35°C.
Certain configurations are validated for temperatures up to 45°C and humidity up to 90 percent, with a 29°C maximum dew point, and are Dell Fresh Air compliant.