NOVUS TM-619 Timer is an electronic device that allows switching of electrical loads (alarms, household appliances, etc.) at programmed time intervals. It can be programmed up to eight (8) ON/OFF programs, which can activate electrical loads at specific times throughout the week. It has an automatic battery, which retains programming and internal clock for several weeks, even in case of power failure.
The NOVUS TM-619 is an electronic programmable timer that switches electrical loads at programmed intervals with good precision. It can store up to eight ON/OFF programs and uses a battery to retain programming and the internal clock for several weeks during a power outage.
The manual describes the ON, AUTO, and OFF operating modes, updating day, hour, and minute, programming ON/OFF cycles, display identification, reset, and CR-2032 battery replacement. The output is a relay with NA, C, and NF (SPDT) terminals, and the relay is not activated during a power outage. This manual is written in Portuguese.
| Power supply | 12 Vdc, 24 Vdc, 110 Vac or 240 Vac, 50/60 Hz |
|---|---|
| Minimum switching interval | 1 minute |
| Output | Relay 16 A / 250 Vac resistive; 8 A / 250 Vac inductive |
| Operating temperature | 0 to 60 °C |
| Storage temperature | -10 to 75 °C |
| Number of programs | Up to 8 ON/OFF programs |
| Output terminals | NA, C, and NF (SPDT) |
| Battery | CR-2032 |
It can store up to eight (8) ON/OFF programs.
It uses a CR-2032 battery.
The operating modes are ON, AUTO, and OFF.
The minimum switching interval is 1 minute.