The GTS series of solid state relays use zero voltage switching technology and are available with current ratings from 10A to 120A and voltage ratings of 230Vac and 480Vac. There are versions with bidirectional thyristors and versions with thyristors. All models are designed to guarantee operation at rated currents, with continuous conduction of power, at a working temperature of 40°C.
This user's manual covers the Gefran GTS series of power solid state relays with logic control, including GTS-T 10/20 TRIAC versions and GTS 15 to 120A SCR versions. The relays switch at zero crossing of the mains voltage and are rated for nominal currents from 10A to 120A at 230Vac or 480Vac.
The manual provides technical data, control input and output ratings, insulation and environmental conditions, installation notes, front-panel descriptions, dimensions, operating types, wiring examples, dissipation curves, terminal characteristics, and available accessories such as fuses, fuse holders, DIN-rail and panel mounting supports. This manual is written in Italian.
| Nominal operating voltage | 230Vac (max. range 24...280Vac) or 480Vac (max. range 24...530Vac) |
|---|---|
| Nominal frequency | 50/60Hz |
| Category of use | AC1 |
| Control input max absorption | 10mA @32V |
| GTS-T10 rated current | 10 A@40°C in servizio continuo |
The control voltage is 5...32Vdc.
Maximum relative humidity is 50% at 40°C.
Maximum installation altitude is 2000m above sea level.