This manual provides operating instructions for the KROHNE H250 M40 series of variable area flowmeters.
This document is the user manual for the KROHNE H250 M40 variable area flowmeter, designed for measuring gases, vapors, and liquids. It provides comprehensive instructions on safety, intended use, and installation conditions, including specific requirements for magnetic and mechanical filters to prevent damage from ferromagnetic particles or solids.
The manual details the electrical connections for the M40 indicator, including limit switches, current outputs, pulse outputs, and Fieldbus/Hart communication. It also covers the startup procedure, operation modes, menu navigation, and error messages. Furthermore, it outlines maintenance procedures, such as replacing dampers and limit switches, and provides a list of spare parts and recycling instructions. This manual is written in Spanish.
| Intended Use | gases limpios, vapores y líquidos |
|---|---|
| Electromagnetic Compatibility | Group 1, Class A |
| Product Name | H250 M40 |
It is suitable for measuring clean gases, vapors, and liquids.
Avoid overpressure and pulsating flow.
It is intended for use in an industrial environment.
The operator is responsible for the equipment's suitability for the specific purpose.