PCE Instruments PCE-CT 65 Coating Thickness Gauge User Manual

This manual describes how to use the PCE-CT 65 Coating Thickness Gauge, which can measure the coating thickness of ferrous and non-ferrous metals.


PCE Instruments PCE-CT 65 Coating Thickness Gauge User Manual - cover page
Brand
PCE Instruments
Category
sensor
Document type
User Manual
Language
Spanish
Pages
25
File format
PDF
File size
845 KB
Published
17 November, 2023
Updated
17 November, 2023
MD5 checksum
F015A8EE7205B894F0E58B5D845C5A0B

About this manual

The PCE-CT 65 is a handheld coating thickness gauge that uses magnetic induction for ferrous metals and eddy current for non-ferrous metals. It offers a measuring range of 0–1350 µm (0–53.1 mils) with selectable units, data storage in 30 working modes, and USB connectivity for data transfer.

The manual provides safety instructions, technical specifications, device and display descriptions, battery replacement, measurement procedures, settings (units, backlight, auto power-off), calibration steps for zero points on both metal types, troubleshooting, warranty, and disposal information. This manual is written in Spanish.

What's inside

  • Safety notes
  • Specifications
  • System description
  • Getting started
  • Operation
  • Calibration
  • Maintenance
  • Warranty
  • Disposal

Specifications

Sensor typeF (ferrous) and N (non-ferrous)
Measuring principle (F)Magnetic induction
Measuring principle (N)Eddy current
Measuring range0 … 1350 µm (0 … 53.1 mils)
Accuracy (0–1000 µm)±(2.5% + 2 µm)
Accuracy (1000–1350 µm)±3.5%
Resolution (0–100 µm)0.1 µm
Resolution (100–1000 µm)1 µm
Resolution (1000–1350 µm)0.01 µm
Minimum curvature radius (F)1.5 mm
Minimum surface diameter (F)7 mm
Smallest measurable thickness (F)0.5 mm
Operating conditions0 … +40 °C, 20 … 90% RH

Frequently asked questions

What is the measuring range of the PCE-CT 65?

The gauge measures coating thickness from 0 to 1350 µm (0 to 53.1 mils) on both ferrous and non-ferrous metals.

How do you perform zero calibration on the PCE-CT 65?

Zero calibration for ferrous and non-ferrous metals is described in section 6.1; zero points can be deleted in section 6.2.

What are the operating temperature and humidity limits?

The device operates from 0 to +40 °C and 20 to 90% relative humidity.

How many working modes does the gauge have and how is data stored?

The gauge has 31 working modes; mode 0 does not store data, while the other 30 modes can each store up to 30 readings in a circular memory.