Viessmann 5200 5201 Transformer Operation Manual

This product is a power transformer that can convert AC power to 16 volts with a maximum output power of 52 VA.


Viessmann 5200 5201 Transformer Operation Manual - cover page
Brand
Viessmann
Category
transformer
Document type
User Manual
Language
English
Pages
4
File format
PDF
File size
710 KB
Published
17 November, 2023
Updated
17 November, 2023
MD5 checksum
B2A7C18C2820E8B4A7EA1A946AAF4C4A

About this manual

This operation manual covers Viessmann Modelltechnik GmbH transformers item 5200 (16 V, 52 VA) and item 5201 (16 V, 150 VA). They are intended for installation in model train layouts and dioramas, connection to a 230 V~/50 Hz socket, and power supply of lighting and solenoid accessories on analogue or digital model train layouts, for operation in dry rooms only.

The manual provides safety instructions, package contents, connection and mounting instructions, cable cross-section requirements, troubleshooting for overload protection, and technical data for both models. The transformer casing must never be opened, and repairs must be done only by Viessmann service staff.

What's inside

  • Important information
  • Safety instructions
  • Using the product for its correct purpose
  • Checking the package contents
  • Introduction
  • Connection
  • Cable cross-sections
  • Mounting
  • Trouble-shooting
  • Technical data

Specifications

5200 Input voltage (primary)230 V~ 50 Hz
5200 Output voltage (secondary)10 and 16 V~
5200 Output current at 16 V (secondary)3.25 A
5200 Output power at 16 V (secondary)52 VA
5200 DimensionsL 130 x W 70 x H 50 mm
5201 Input voltage (primary)230 V~ 50 Hz
5201 Output voltage (secondary)9 and 16 V~
5201 Output current at 16 V (secondary)9.25 A
5201 Output power at 16 V (secondary)150 VA
5201 DimensionsL 179 x W 89 x H 81 mm

Frequently asked questions

What is the Viessmann transformer intended for?

It is intended for installation in model train layouts and dioramas and for power supply of lighting circuits or solenoid accessories on analogue or digital operated model train layouts, for operation in dry rooms only.

What should be done if the overload protection is activated on transformer 5200?

Unplug all transformers from the power socket, search for and correct the short-circuit, then plug the transformers in again after approximately 1 minute.

May the transformer casing be opened?

No. Never open the casing of the transformer; all repairs to the transformer or its power cable must be done only by Viessmann service staff.

What minimum cable cross-section must be used for wiring?

Use only wires with a minimum cable cross-section of 0.75 mm²; smaller or longer cables may overheat in case of short-circuit.

Download PDF (710 KB)

More Viessmann Manuals


View all Viessmann manuals →