Fire and Security MPSR Series Outdoor Manual Station Installation Sheet. The product features: 10 A snap action switch and gold contacts, can be used with or without a break glass rod, no special tools required for replacement.


UTC Fire & Security MPSR Series Outdoor Manual Station Installation Sheet - cover page
Brand
UTC Fire & Security
Category
Other products
Document type
Installation Guide
Language
English
Pages
2
File format
PDF
File size
382 KB
Published
16 November, 2023
Updated
16 November, 2023
MD5 checksum
6FAAC04123E26F8B041EC95A0C5BC09E

About this manual

UTC Fire & Security MPSR Series Outdoor Manual Station Installation Sheet provides installation instructions for single-action and double-action outdoor manual pull stations. It lists covered model numbers and describes mounting the backbox, wiring, glass rod installation, and faceplate locking.

Additional sections cover two- and six-contact terminal block wiring diagrams, glass rod replacement, station reset, and specifications including dimensions, mounting, contact ratings, locking mechanism, and operating environment.

What's inside

  • Product description
  • Installation instructions
  • Wiring diagrams
  • Replacing the glass rod
  • Resetting a manual station
  • Specifications

Specifications

Width3.325 in. (8.445 cm)
Height4.750 in. (12.065 cm)
Depth0.875 in. (2.22 cm) single action, 1.5 in. (3.8 cm) double action
MountingSingle-gang weatherproof backbox (included)
WiringTwo or six contact terminal block depending on model
Power switch rating10 A at 120 VAC
Gold contact rating1.0 A at 120 VAC
Key switch rating0.5 A at 30 VDC
Locking mechanismStandard key or hex key
OperationSingle action or double action depending on model
Operating temperature30 to 150°F (−35 to 66°C)
Operating humidity0 to 85% RH, noncondensing

Frequently asked questions

Which MPSR models does this installation sheet cover?

It covers the single-action and double-action MPSR outdoor manual station models listed in the product description.

How do you replace a broken glass rod?

Open the faceplate, remove debris, make sure the pull-down handle is closed, insert the rod under one spring tab, lift the other spring tab, and close and lock the faceplate.

Can an activated manual station be reset?

Yes; open the faceplate, close the pull-down handle, replace the glass rod if one is being used, then close and lock the faceplate.

What are the contact ratings?

The power switch is rated 10 A at 120 VAC, gold contacts are rated 1.0 A at 120 VAC, and the key switch is rated 0.5 A at 30 VDC.