UTC Fire & Security DC107 Series Magnetic Contact Installation Sheet

Installation sheet for UTC Fire & Security DC107 series flush-mounted magnetic contacts used with burglar alarm systems.


UTC Fire & Security DC107 Series Magnetic Contact Installation Sheet - cover page
Brand
UTC Fire & Security
Category
Other Electronics
Document type
Installation Guide
Language
English
Pages
10
File format
PDF
File size
455 KB
Published
08 November, 2026
Updated
08 November, 2026
MD5 checksum
129EC5B0EEDD0401A1FF758EF2C12107

About this manual

UTC Fire & Security DC107 series are flush-mounted magnetic contacts that can be connected to a burglar alarm system. They can be used in ferromagnetic environments and doors.

The sheet covers mounting, wiring, package contents, specifications, regulatory information, certification, and product warnings. Switching distances must be determined individually during installation, and the electrical switch function must be checked after installation.

What's inside

  • Description
  • Mounting
  • Wiring description
  • Package content
  • Specifications
  • Regulatory information
  • Product warnings and disclaimers
  • Certification
  • Contact information

Specifications

Cable length (DC107, DC107R4.7)2.5 m
Cable length (DC107S60)6 m
Switch close resistance (DC107, DC107S60)< 2 Ω
Switch close resistance (DC107R4.7)4.7 kΩ ±10%
Switch open resistance (DC107, DC107S60)> 10 MΩ
Switch open resistance (DC107R4.7)9.4 kΩ ±10%
Approach distance Y (switch close)13 mm ±25%
Removal distance Y (switch open)15 mm ±25%
Approach distance Z (switch close)10 mm ±35%
Removal distance Z (switch open)12 mm ±35%
Contact typeNC
Maximum switch voltage50 V
Maximum switch current0.5 A
Contact dimensionsØ24 x 28.6 mm
Magnet dimensionsØ24 x 39.7 mm
Borehole diameter19.1 mm
Operating temperature−40 to +65°C
Operating temperature (EN 50131 Class II)−10 to +55°C
Environmental classIP68
CertificationEN50131-2-6: 2008 Security Grade 2, Class II

Frequently asked questions

What are DC107 series magnetic contacts used for?

They are flush-mounted magnetic contacts that can be connected to a burglar alarm system.

Can the DC107 series be used in ferromagnetic environments?

Yes, the DC107 series can be used in ferromagnetic environments and doors.

What must be checked after installation?

The electrical switch function of the magnetic contact must be checked, for example with a continuity checker or multimeter.

What is the environmental class of the DC107 series?

The environmental class is IP68.