Installation and programming manual for the UTC Fire & Security Advisor Advanced ATSx000A(-IP) security control panel system.
This manual provides detailed instructions for installing and programming the Advisor Advanced ATSx000A(-IP) security control panel. It covers general installation information, including mains power connection, battery replacement, and mounting procedures. The guide also details system configuration, zone setup, output addressing, and user management.
| Mains input voltage | 230 VAC +10%, −15%, 50 Hz ±10% |
|---|---|
| Power supply voltage | 13.8 V ±0.2 V |
| Battery type | Lead acid rechargeable, 7.2 Ah 12 V nom. (BS127) or 18 Ah 12 V nom. (BS131) |
| Maximum system current available | ATS1000A 1000 mA, ATS2000A 2000 mA |
This document applies to the following Advisor Advanced firmware versions: ATSx000A (-IP): V026.026.130.
Users should have basic knowledge of alarm systems and components, as well as basic knowledge of electrical wiring and low-voltage electrical connections.
The maximum ripple voltage is 300 mV, with a typical value of 100 mV.