The DT-311J is a digital stroboscope designed to assist in mechanical timing adjustments and to emit flashes synchronously with an external signal and an internal signal.
This is the English instruction manual for the Shimpo DT-311J and DT-311J-230V(AC) digital stroboscope. It explains that the instrument is designed to assist mechanical timing adjustments and to emit flashes synchronously with an external signal or an internal signal, with flashes delayable from 0 up to 359 degrees at a positive edge of an external signal and the delayed angle shown on the LED display. Revolutions per minute (RPM) can also be displayed.
The manual covers safety instructions, specifications, front and rear panel diagrams, cable connection, mode selection, internal and external signal operation, divide ratio and phase shift settings, flash interval diagrams, the lamp on/off switch, low and high speed alarms, input circuitry, lamp replacement and the initial reset procedure. A 6 m (19') cable with connector, the instruction manual and a warranty card are listed as included accessories.
| Flashing range | 200 – 1,500 rpm |
|---|---|
| Phase shift | 0 – 359º |
| Divided ratio | 1/1, 1/2, 1/3, 1/4, 2/4 with shift |
| Display | 4 digits, 10 mm high, red LED |
| Input impedance | 47k ohms |
| Accuracy | +/- 1 digit |
| Flash tube | Xenon lamp, max 10 W at 1,500 rpm, life 100 million flashes |
| Operating temperature | 32º - 104º F (0 - 40º C) |
| Power requirement | 110 VAC, (230 VAC model) +/-10% at 50/60 Hz |
| Power consumption | 20 VA MAX |
| Dimensions | 8.43”L x 5.87”W x 6.85”H (214 mm x 149 mm x 174 mm) |
| Weight | 4.19 lb (1.9 kg) |
The flashing range is 200 to 1,500 rpm, which is also the internal signal range.
Simultaneously press the LAMP ON/OFF button and ZERO, then press the Power switch on. The memory is cleared and the factory default condition resumes.
Only the specified lamp, FLASHTUBE311-J, should be used for replacement.
The “over” symbol appears as a high speed indicator, and the stroboscope flash will not function while the alarm symbol is shown.