Key facts
- Manuals
- 2
- Languages
- EN · ZH
- Last added
- 2026-09-29
Featured Shimpo manuals

Shimpo DT-311N / DT-315N Stroboscope User Manual
This manual covers the Shimpo DT-311N and DT-315N stroboscopes, detailing their dimensions, specifications, and safety instructions. It explains how to set up the unit, whether handheld or mounted on a tripod, and describes the functions of the display panel and control switches.
The guide also includes detailed procedures for operating the stroboscope in internal and external trigger modes, replacing the flash tube and battery, adjusting memory parameters, and troubleshooting common issues such as a non‑flashing unit or out‑of‑range input signals.
Covers: Dimensions & Specifications · General Safety and Features · Setup and Mounting · Operation Display Panel · Internal Triggering Mode · External Triggering Mode

Shimpo DTMB Series Digital Tension Measuring Instrument User Manual
This manual provides step‑by‑step instructions for using the Shimpo DTMB series digital tension measuring instrument. It includes details on battery installation, thickness adjuster use, built‑in memory functions, and how to set measurement conditions.
The document also lists technical specifications such as measurement range, RS‑232C output parameters, dimensions, weight, power options, and operating temperature, helping users configure and maintain the instrument correctly. This manual is written in Chinese.
Covers: Overview · Battery Installation/Replacement · Thickness Adjuster · Operation · Built‑in Memory System · Measurement Settings
Latest Shimpo manuals
Shimpo DT-311N / DT-315N Stroboscope User Manual
User Manual 2 pages · 1.3 MB · ENThe Shimpo DT-311N and DT-315N stroboscope manual provides specifications, setup, operation, troubleshooting, and maintenance instructions.
Shimpo DTMB Series Digital Tension Measuring Instrument User Manual
User Manual 10 pages · 880 KB · ZHOperation manual for Shimpo DTMB digital tension measuring instrument, covering battery installation, calibration, and measurement settings.
Which document do I need?
User Manual
Day-to-day operation, settings and troubleshooting. Start here if the product is already set up.
Questions answered in Shimpo manuals
What should I do if the FPM reading is displayed but the unit is not flashing?
Replace the flash tube as described in the Flash Tube Replacement section.
How can I change the decimal point setting on the stroboscope?
Press “¸2” and “‑” together for about 2 seconds until the display alternates, then press “+” to select the desired decimal point.
How is the zero (gravity) calibration performed?
Press and hold the two keys simultaneously until the display shows "0" or "0.0" to complete the zero calibration.
From: Shimpo DTMB Series Digital Tension Measuring Instrument User Manual
What does the "BATT" indicator mean?
It indicates low battery voltage; data stored in memory may be lost if the batteries are removed.
From: Shimpo DTMB Series Digital Tension Measuring Instrument User Manual