The WATERFLUX 3070 is an electromagnetic flowmeter with the following features: - High accuracy: The measuring accuracy is up to 0.5% - High stability: The long-term stability is up to 0.1% - High reliability: The mean time between failures is up to 10 years - Low power consumption: The battery life is up to 10 years - Easy to install and use: Can be installed and used without special tools
KROHNE's reference manual for the WATERFLUX 3070 battery-powered electromagnetic water meter covers safety instructions, device description, mounting, electrical connection, commissioning, programming, maintenance and technical specifications. It applies to electronic revision 5.0.5_ (SW.REV.5.0.2_) and is issued as document MA WATERFLUX 3070 - R02 of 05/2020.
Mounting guidance covers straight upstream and downstream lengths, T-sections, elbows, pumps, control valves, air purging and vacuum, installation in measuring chambers and buried applications, and tightening torques. The programming chapters describe display and control elements, access control with metrological seals for commercial transactions, the menu structure, totalizers and flow, pulse and status outputs, pressure and temperature parameters, battery parameters and Modbus settings, as well as automatic self-test, verification mode and test mode. Maintenance covers replacing the internal and external battery and the KROHNE FlexPower unit. This manual is written in French.
| Intended use | Flow measurement of potable water and raw water |
|---|---|
| Measuring principle | Electromagnetic water meter |
| Electronic revision | 5.0.5_ |
| Software revision | SW.REV.5.0.2_ |
| Housing protection | IP68 (compact and separate versions) |
| EU approval | Directive 2014/32/EU, Annex III (MI-001) |
| Optional power supply | KROHNE FlexPower |
| Optional communication | Modbus protocol |
It is designed exclusively to measure the flow of potable water and raw water.
It can be operated from an internal battery or an external battery, and optionally from a KROHNE FlexPower unit.
It meets Directive 2014/32/EU, Annex III (MI-001), among other approvals and standards.
Yes, the technical specifications include an optional Modbus protocol and the menu has Modbus settings.