This document describes an advanced non-contact temperature screening solution that can help businesses safely reopen during the COVID-19 pandemic. The solution uses thermal imaging technology to measure body temperature and can screen individuals in seconds. It can also be integrated with advanced video management software to provide centralized management of temperature screening data.
This Spanish-language technology application guide from Avigilon explains how to implement a non-contact temperature screening solution using the Avigilon H4 Thermal ETD camera together with the Avigilon Control Center (ACC) 7 video management software. It describes the benefits of the approach, including screening without contact so social distancing can be maintained, faster throughput of people at entrances, and elevated-temperature alerts that let an operator monitor readings from a safe workstation.
The guide gives step-by-step placement and setup advice: designating entries and control points, marking social distancing, pairing the thermal camera with a blackbody temperature reference calibrated to 35°C (95°F), controlling ambient conditions between 18 and 24°C (65 and 75°F), avoiding reflective backgrounds, and screening one person at a time. It also covers how ACC 7 shows temperature readings in the face bounding box with three detection categories, adjustable alarm thresholds, and cloud reports such as a COVID-19 response dashboard. This manual is written in Spanish.
| Skin temperature measurement accuracy | ±0.5°C (±0.9°F) with a precalibrated blackbody device |
|---|---|
| Blackbody reference temperature | 35°C (95°F) |
| Ambient room temperature for accuracy | 18 to 24°C (65 to 75°F), indoors without drafts |
| Camera distance from person | 1.5 m (5 ft) |
| Camera height | 1.5 to 2 m (5 to 6.5 ft) from the floor on a tripod |
| Blackbody distance from camera | 1.5 m (5 ft) |
| Screening throughput | Up to 10 people per minute |
| Elevated temperature alarm interval | 0.1°C / 0.1°F |
The guide places the thermal camera on a tripod 1.5 m (5 ft) from the person, at a height of 1.5 to 2 m (5 to 6.5 ft) from the floor.
A temperature control solution reduces screening time to a few seconds and allows up to 10 people per minute to pass.
Working with a precalibrated blackbody device as a reference point, it measures human skin temperature with an accuracy of ±0.5°C (±0.9°F).
The guide recommends keeping the room between 18 and 24°C (65 and 75°F), indoors and free of drafts from radiators or air conditioning.