This is the V1.0 user manual for the Renke RS-CZQXZ vehicle-mounted weather station, an integrated automatic weather observation device made up of a case-style collection instrument and a combined sensor unit, designed for vehicles, ships and other moving platforms. The text states that the station combines wind speed and wind direction (measured by ultrasonic principle), temperature, humidity, noise, PM2.5 and PM10, CO2 and atmospheric pressure, with light intensity also listed in the specifications, and that it outputs data over RS485 using the standard ModBus-RTU protocol. Devices with a built-in electronic compass need only be mounted level, and a 4G option uploads collected data to a cloud platform.

The manual covers the product introduction and technical specifications, device dimensions, installation (magnetic bases or an I-beam frame fixed to a roof luggage rack), connecting the sensor to the collection instrument and exporting stored data by USB drive, installation and use of the 485 parameter configuration software, the communication protocol with register addresses and example frames, common problems and solutions, and contact information. This manual is written in Chinese.

What's inside

  • Product Introduction
  • Technical Specifications
  • Product Selection Codes
  • Device Dimensions
  • Installation Instructions
  • Configuration Software Installation and Use
  • Communication Protocol
  • Common Problems and Solutions
  • Contact Information
  • Document History

Specifications

Power supply10-30 VDC (default DC supply)
Maximum power consumption (RS485 output)1.2 W
Wind speed measuring range0~60 m/s
Wind direction measuring range0~359°
Temperature measuring range-40℃~+80℃
Humidity measuring range0%RH~99%RH
Atmospheric pressure measuring range0-120 kPa
Noise measuring range30dB~120dB
PM2.5 / PM10 measuring range0-1000 μg/m³
CO2 measuring range0-5000 ppm
Light intensity measuring range0~200,000 Lux
Output signalRS485, standard ModBus protocol
Maximum communication distanceup to 2000 m
Baud rate2400, 4800 or 9600 bit/s selectable; factory default 4800 bit/s
Default device address0x01

Frequently asked questions

What are the default address and baud rate of the station?

The default address is 0x01 and the default baud rate is 4800 bit/s. The baud rate can also be set to 2400 or 9600 bit/s.

Can the collected data be exported?

Yes. The collection instrument stores the collected data automatically, and the data can be exported through a USB drive.

Does the station have to be installed facing a particular direction?

No. For devices with a built-in electronic compass there is no orientation requirement; it is enough to make sure the installation is level.

What should I check if the device cannot connect to a PLC or computer?

The manual lists causes such as a wrong COM port, a wrong or duplicated device address, wrong baud rate/parity/data bits/stop bits, or a broken 485 bus with the A and B wires reversed.