The RS-EVA-N01-2 evaporation transmitter is a device developed by our company to observe water evaporation. It adopts a double stainless steel structure design to prevent evaporation errors caused by direct sunlight. The measurement accuracy is more accurate, and the whole machine is made of 304 stainless steel. The appearance is exquisite and corrosion-resistant, which can effectively ensure the service life of the sensor. It uses a digital sensor with high measurement accuracy, wide range, high sensitivity, no temperature drift, time drift, and long-term stable performance. The device adopts standard ModBus-RTU 485 signal output.
The RS-EVA-N01-2 is an evaporation transmitter made by Shandong Renke Measurement & Control Technology Co., Ltd. for observing water surface evaporation. It uses a double-layer stainless steel structure to reduce errors caused by direct sunlight, and measures evaporation with a pressure/weight principle by weighing the liquid in the evaporation pan to calculate the liquid level height. The device outputs a standard ModBus-RTU 485 signal and is built from 304 stainless steel.
The manual covers product introduction and selection, wiring and installation, device dimensions, and the ModBus-RTU communication protocol, including basic communication parameters, data frame format, register addresses, and communication examples. The transmitter is intended for meteorological observation, plant cultivation, seed cultivation, agriculture and forestry, geological survey, and scientific research, and can be paired with automatic water-adding devices, data acquisition and transmission devices, and rain sensors. This manual is written in Chinese.
| Supply Voltage | 10-30VDC |
|---|---|
| Power Consumption | 0.17W |
| Measuring Range | 0~200mm |
| Measuring Accuracy | ±1%FS |
| Response Time | <1s |
| Output Type | Standard ModBus-RTU protocol, 485 signal output |
| Protection Rating | IP66 |
| Inner Cylinder Diameter | 18.4cm |
| Inner Cylinder Height | 20cm |
| Operating Temperature | -40~85℃ |
| Operating Humidity | 0~100%RH |
| Storage Temperature | -40~125℃ |
| Storage Humidity | <80% (no condensation) |
It uses a pressure/weight principle: it measures the weight change of liquid in the evaporation pan with a high-precision weighing method, then calculates the liquid level height to obtain evaporation.
It provides a standard ModBus-RTU protocol 485 signal output.
The measuring range is 0~200mm and the measuring accuracy is ±1%FS.
Baud rates of 2400bit/s, 4800bit/s and 9600bit/s are selectable, with 4800bit/s as the factory default.