BrightKing GDT Ceramic Gas Discharge Tubes Selection Guide

BrightKing GDT product line includes two-electrode and three-electrode gas discharge tubes, featuring low junction capacitance, high current capacity, DC breakdown voltage range of 75V~6000V, impulse breakdown voltage range of 600V~7800V, high insulation resistance, etc. They are widely used in communication, security, industrial and other electronic products for communication lines and power line protection.


BrightKing GDT Ceramic Gas Discharge Tubes Selection Guide - cover page
Brand
BrightKing
Category
electronic components
Document type
Application Note
Language
Chinese
Pages
10
File format
PDF
File size
1.5 MB
Published
15 November, 2023
Updated
15 November, 2023
MD5 checksum
82B8FA50AFE2FF9D4071374349BB119A

About this manual

This selection guide from BrightKing introduces the company's ceramic gas discharge tubes (GDTs), sealed components containing one or more discharge gaps filled with inert gas, used to protect electronic equipment and people from transient high voltages. Their electrical performance depends on gas type, gas pressure and electrode structure, and they combine very low capacitance with high surge current capability and insulation resistance generally above 1 GΩ.

The guide explains the GDT working principle and volt-ampere characteristics, shows typical applications on AC power lines (with the GDT in series with an MOV or TVS) and on RJ45, RS485 and BNC interfaces, and walks through parameters such as DC spark-over voltage, impulse spark-over voltage, nominal impulse discharge current and impulse life, with test circuits based on GB/T 18802.311 (IEC 61643-311). It closes with selection notes, the part numbering rules and tables of BrightKing's two-electrode and three-electrode GDT product lines. This manual is written in Chinese.

What's inside

  • GDT working principle
  • GDT features
  • GDT typical application circuits
  • GDT parameter explanations
  • DC spark-over voltage
  • Maximum impulse spark-over voltage
  • Nominal impulse discharge current
  • Impulse life
  • GDT selection notes
  • GDT naming rules

Specifications

DC spark-over voltage range75 V – 6000 V
Impulse spark-over voltage range600 V – 7800 V
Surge current capability (8/20μs)500 A – 100 kA
Capacitance (most series)≤ 2 pF
Insulation resistancetypically ≥ 1 GΩ
2RP600L-8 DC spark-over voltage600 V ±20%
2RP600L-8 maximum impulse spark-over voltage1300 V

Frequently asked questions

What is the DC spark-over voltage of a GDT?

It is the voltage at which the GDT sparks over when a slowly rising DC voltage is applied, measured at a rise rate of no more than 100 V/s; it is also called the DC breakdown voltage.

Can a GDT be used alone on an AC power line?

No. For power line protection the GDT must be connected in series with an MOV or TVS, because after it conducts its voltage is low and it can remain conducting.

How is the impulse spark-over voltage of a GDT measured?

After the unpowered GDT rests in darkness for at least 15 minutes, a voltage with a rise rate of 1000 (1±10%) V/μs is applied and the maximum voltage before discharge is recorded.

What is the follow-current problem with GDTs?

If the working voltage of the protected circuit is higher than the GDT's on-state voltage after it conducts, the GDT stays conducting, and a prolonged ampere-level current can damage the GDT and the circuit.