BrightKing GDT product line includes two-electrode and three-electrode gas discharge tubes, featuring low junction capacitance, high current capacity, DC breakdown voltage range of 75V~6000V, impulse breakdown voltage range of 600V~7800V, high insulation resistance, etc. They are widely used in communication, security, industrial and other electronic products for communication lines and power line protection.
This selection guide from BrightKing introduces the company's ceramic gas discharge tubes (GDTs), sealed components containing one or more discharge gaps filled with inert gas, used to protect electronic equipment and people from transient high voltages. Their electrical performance depends on gas type, gas pressure and electrode structure, and they combine very low capacitance with high surge current capability and insulation resistance generally above 1 GΩ.
The guide explains the GDT working principle and volt-ampere characteristics, shows typical applications on AC power lines (with the GDT in series with an MOV or TVS) and on RJ45, RS485 and BNC interfaces, and walks through parameters such as DC spark-over voltage, impulse spark-over voltage, nominal impulse discharge current and impulse life, with test circuits based on GB/T 18802.311 (IEC 61643-311). It closes with selection notes, the part numbering rules and tables of BrightKing's two-electrode and three-electrode GDT product lines. This manual is written in Chinese.
| DC spark-over voltage range | 75 V – 6000 V |
|---|---|
| Impulse spark-over voltage range | 600 V – 7800 V |
| Surge current capability (8/20μs) | 500 A – 100 kA |
| Capacitance (most series) | ≤ 2 pF |
| Insulation resistance | typically ≥ 1 GΩ |
| 2RP600L-8 DC spark-over voltage | 600 V ±20% |
| 2RP600L-8 maximum impulse spark-over voltage | 1300 V |
It is the voltage at which the GDT sparks over when a slowly rising DC voltage is applied, measured at a rise rate of no more than 100 V/s; it is also called the DC breakdown voltage.
No. For power line protection the GDT must be connected in series with an MOV or TVS, because after it conducts its voltage is low and it can remain conducting.
After the unpowered GDT rests in darkness for at least 15 minutes, a voltage with a rise rate of 1000 (1±10%) V/μs is applied and the maximum voltage before discharge is recorded.
If the working voltage of the protected circuit is higher than the GDT's on-state voltage after it conducts, the GDT stays conducting, and a prolonged ampere-level current can damage the GDT and the circuit.