This product is a 1500 / 2500 VA corona treater, with stringent requirements and environmental conditions, designed for the woven sack industry. The treater will continue to provide trouble-free service for years to come.
This manual describes the 1500 VA / 2500 VA corona treater (regular model with power control feature), Document No. CT-2a, updated 16/10/2015. The treater is designed for the requirements and environmental conditions of the woven sack industry and uses a microcontroller to handle on/off, protection, safety and oscillator control, with an IGBT/MOSFET power inverter stage and an operating frequency of about 18 kHz.
The manual covers the construction of the sheet metal cubicle panel with two independent roller assemblies, the oil-cooled HT transformers, operation of the panel including auto/manual mode and the speed interlock, the digital inputs and outputs on the Euro connector PCB, status lamp fault indications, power control via increase/decrease switches, maintenance precautions and a troubleshooting guide.
| Operating frequency | about 18 kHz |
|---|---|
| Frequency POT dispatch setting | 17 kHz maximum limit (adjustable approx. 16.5–19 kHz) |
| Required current, 1500 VA | 10 Amp - 15 Amp |
| Required current, 2500 VA | 20 Amp - 25 Amp |
| HT clearance from ground potential | 75 mm |
| Digital outputs | Open collector, 24 VDC, 50 mA maximum |
| Control transformer secondary | 9V AC and 18V AC |
A regular flash means the treater is ready; one flash means the corona ON/OFF switch was left ON at power-up, two flashes mean a safety interlock is open, three flashes indicate an over current fault, and four flashes indicate over temperature of the electronic module heat sinks.
Switch OFF the corona ON/OFF switch; the status lamp will then flash at regular interval to indicate the ready position.
In manual mode the corona stays ON even if the silicon roller does not rotate, so it is used only for trial; automatic mode should be used in normal operation.
Periodically check the oil level in the HT transformer and top up with tested oil if it is not up to the mark.