This kit is used for in vitro qualitative detection of nasopharyngeal swabs, oropharyngeal swabs, and alveolar lavage fluids of suspected cases of pneumonia, suspected aggregation cases, and other patients who need to be diagnosed or differentially diagnosed for new coronavirus infection.
This instructions manual describes the Corona Virus Disease 2019 (COVID-19) Nucleic Acid Detection Kit (Real-Time PCR Method), product Cat. No. RP-010, packed as 100 tests per box. The kit is intended for in vitro qualitative detection of SARS-CoV-2 in nasopharyngeal swabs, oropharyngeal swabs, and alveolar lavage fluids from suspected pneumonia cases, suspected aggregation cases, and other patients requiring diagnosis or differential diagnosis of new coronavirus infection. It targets the ORF1ab and N gene sequences published on the GISAID platform using one-step fluorescence PCR with specific primers and Taqman probes, and includes an internal standard to monitor sample collection, extraction and reaction and avoid false negatives.
The manual lists the kit components (reaction solution, mixed enzyme solution, positive and negative controls), storage requirements, applicable PCR instruments, sample collection requirements, and a step-by-step testing method covering reagent preparation, RNA extraction, PCR setup with cycling parameters, quality control procedures, and interpretation of results. A performance section reports specificity, cross-reaction testing against related pathogens, precision limits, and control coincidence rates.
| Packing specification | 100 Tests/Box |
|---|---|
| Product Cat. No. | RP-010 |
| Target genes | ORF1ab and N genes |
| Storage | -20℃±5℃, protected from light |
| Shelf life | 6 months |
| PCR reaction volume | 20μL per well |
| Applicable instrument | ABI7500 quantitative fluorescence PCR instrument |
| Precision | CV not higher than 5.0% |
| Control coincidence rate | 100% |
Store frozen at -20℃±5℃ and protected from light; the expiration date is 6 months. Avoid repeated freezing and thawing, which must not exceed 7 times.
The kit is suitable for the ABI7500 quantitative fluorescence PCR instrument. Other FAM, VIC/HEX and Cy5 platforms such as QuantStudio, Bio-Rad, Roche LightCycler 480II and SLAN-96S are listed as possible devices, with technical support available on request.
Nasopharyngeal swabs, oropharyngeal swabs, and alveolar lavage fluids of suspected cases of pneumonia and other patients needing diagnosis or differential diagnosis of new coronavirus infection.
A positive result shows an amplification curve with a Ct value ≤40; samples positive for only one target (FAM or VIC alone) are suspected positive and must be re-tested.