This document describes the installation and operation of the Victron Energy VE.Direct series inverters.
The manual covers Victron Energy VE.Direct inverter models listed from 12 | 250 through 48 | 1200. It starts with important safety instructions and describes the VE.Direct communication port, configurable low battery and output settings, monitoring, ECO mode, remote on/off connection, and LED diagnosis.
The installation section covers mounting positions, minimum battery capacity, internal DC fuse ratings, recommended DC cable cross-sections, grounding, AC load connection, neutral-to-chassis connection, remote on/off, and configuration. Operation is explained with green and red LED tables and protection/restart behavior.
| Output voltage | 210 - 245 V |
|---|---|
| Output frequency | 50 Hz or 60 Hz |
| Minimum ECO mode setting | 15 W |
| Output socket options | Schuko, UK (BS-1363), AU/NZ (3112), IEC-320 |
| Protection | Short circuit proof and protected against overheating |
| Minimum battery capacity (12/250 model) | 30 Ah |
The VE.Direct port can be connected to a computer with a VE.Direct to USB interface cable.
Reduce the load.
The minimum ECO mode setting is 15 W.
No. Never connect the inverter output to another AC source such as a household wall outlet or generator.