Victron Energy MultiPlus 500VA‑2000VA Inverter/Charger Product Data Sheet

Technical overview of Victron Energy's MultiPlus inverter/charger range from 500 VA to 2000 VA with specs, features and remote monitoring options.


Victron Energy MultiPlus 500VA‑2000VA Inverter/Charger Product Data Sheet - cover page
Brand
Victron energy
Document type
Product Leaflet
Language
English
Pages
2
File format
PDF
File size
527 KB
Published
05 October, 2026
Updated
05 October, 2026
MD5 checksum
613E8E45C914D2780195F5079164635D

About this manual

The MultiPlus series from Vicron Energy combines a true‑sine‑wave inverter, an adaptive‑charge battery charger and a high‑speed AC transfer switch in a single compact enclosure. It offers intelligent power management features such as PowerControl, PowerAssist, Search Mode and a programmable relay, plus optional remote monitoring via the VRM portal.

The product line covers 12 V, 24 V and 48 V systems with continuous output power from 500 VA up to 2000 VA, three‑phase and parallel operation, and a range of safety and protection functions. Detailed electrical ratings, physical dimensions and compliance standards are listed in the specifications section.

What's inside

  • Features
  • Parallel and Three‑Phase Operation
  • PowerControl and PowerAssist
  • Adaptive Charger
  • Search Mode
  • Programmable Relay
  • Remote Monitoring
  • Technical Specifications
  • Physical Characteristics
  • Standards

Specifications

Peak power900 W – 3500 W
Maximum efficiency90 % – 95 %
Zero‑load power (normal mode)6 W – 10 W
Zero‑load power (search mode)2 W – 3 W
Inverter input voltage range9.5‑17 V (12 V), 19‑33 V (24 V), 38‑66 V (48 V)
Output voltage230 VAC ± 2 %
Output frequency50 Hz ± 0.1 %
Charger AC input voltage range187‑265 VAC
Charge voltage (absorption)14.4 V / 28.8 V / 57.6 V
Charge voltage (float)13.8 V / 27.6 V / 55.2 V
House‑battery charge current (max)20 A – 80 A
Operating temperature range-40 °C to +65 °C
Enclosure protection ratingIP 21
Weight (500 VA model)4.4 kg
Dimensions (500 VA model)311 mm × 182 mm × 100 mm (H×W×D)

Frequently asked questions

How many MultiPlus units can be connected in parallel?

Up to six MultiPlus units can operate in parallel to increase total power output.

What is Search Mode and how does it affect power consumption?

When Search Mode is on, the inverter’s no‑load power consumption is reduced by about 70% by switching off the inverter when there is no or very low load.

What are the input voltage ranges for the inverter?

The inverter accepts 9.5‑17 V for 12 V systems, 19‑33 V for 24 V systems, and 38‑66 V for 48 V systems.