The GF PF220/PF330 V2 Ultrasonic Flowmeter is a highly accurate and reliable flowmeter for measuring the flow of liquids and gases. The flowmeter uses advanced ultrasonic technology and has the advantages of high measurement accuracy, wide measuring range, low pressure loss and easy installation.
The GF Piping Systems PF220 V2, PF330 V2 and PF330 V2 HM are clamp-on ultrasonic flowmeters and heatmeters described in this operating manual. The flowmeter uses ultrasonic transit time techniques and a microprocessor system to measure flow in closed pipes with outside diameters from 13 mm to 2000 mm without inserting mechanical parts into the pipe.
The manual covers intended use, design and function, installation and transducer positioning, first-time use, the quick start menu, named sites, calibration parameters, logging functions on the PF330 V2, current loop and digital outputs, status screens, heat meter functions on HM versions, maintenance, troubleshooting, specifications and disposal.
| Pipe outside diameter range | 13 mm to 2000 mm |
|---|---|
| Maximum particulate content | Less than 3% by volume |
| Transducer set A pipe range | 13 mm to 115 mm outside diameter |
| Transducer set B pipe range | 50 mm to 2000 mm outside diameter |
| Internal logging capacity | Up to 200k logging events |
| Transducer cables | 2 cables, 2 m long |
It is designed for pipes with an outside diameter from 13 mm up to 2000 mm.
It can measure clean liquids or oils with less than 3% particulate content by volume, as well as cloudy liquids such as river water and effluent.
Yes. Up to 200k logging events can be stored internally for later download to a USB key.
HM versions are supplied with two RTD PT100 temperature sensor cables.