About this manual

The GF Piping Systems Double-See™ Vinyl Double Containment Piping System is designed for a wide range of applications including water and wastewater treatment, chemical delivery, dosing and processing, microelectronics, life sciences, metal working/finishing, waste collection, and many others. The system features PVC Schedule 80, CPVC Schedule 80, and PVC Schedule 40 materials with specific gravity, linear expansion coefficients, tensile strength, modulus of elasticity, heat distortion temperatures, and flammability ratings (UL94 V-O) detailed in the specification section.

What's inside

  • Material Properties
  • Pipes
  • Elbows
  • Tees
  • Sump
  • Closure Couplings
  • Terminations
  • Valves
  • Leak Detection
  • Accessories

Specifications

Material Cell classification (PVC 80)12454
Specific Gravity (g/cc3 @ 73°F) PVC 801.40
Tensile Strength @ yield (psi @ 73°F) PVC 807,200
Flammability Rating (UL94)V-O
Pressure Rating Secondary (PVC 80)up to 50 psi
Temperature Rating PVC 8032°F–140°F (0°C–60°C)
Temperature Rating CPVC 8032°F–200°F (0°C–93°C)
Material ApprovalsNSF/ANSI 14 & 61, ASTM D1784, ASTM D1785, ASTM D2467, ASTM F441, ASTM F439

Frequently asked questions

What are the main applications for the Double-See system?

The system is suitable for water and wastewater treatment, chemical delivery, dosing and processing, microelectronics, life sciences, metal working/finishing, waste collection, and many others.

Is the Double-See system pressure rated?

The primary pipe varies by size, while the secondary pipe is rated up to 50 psi.

What joining technology is used for this piping system?

The system utilizes solvent cement and packing for installation.

Download PDF (571 KB)