GF Piping Systems product range 2016 for EA25, EA45, EA120 and EA250 electric actuators, with technical details, accessories, configurator codes and valve…
This GF Piping Systems product range document covers the electric actuators EA25, EA45, EA120 and EA250 together with the electric ball valves and butterfly valves built on them. It gives the technical details of the actuators — nominal voltage, protection class, ambient temperature, housing material, nominal power, torque, duty cycle, cycle time, flange fitting, tested cycles, weight and actuating angle — plus a type/code table with voltages, torques and interface codes, and a dimension table.
Further sections list accessories that can be retrofitted (fail-safe return units, positioner, monitoring, Profibus DP board, diagnostic tool), a product configurator for building an actuator code and a ball valve code, valve-to-actuator combinations with interface codes for ball valve type 546, ball valve type 543 and butterfly valves, and the electric ball valve types 179–184, 167–170 and butterfly valve types 145–147 with their dimensions, materials and standards.
| Nominal voltage | AC: 100 – 230 V, 50/60 Hz; AC/DC: 24 V, 50/60 Hz |
|---|---|
| Nominal voltage tolerance | ± 15% |
| Protection class | IP 65 (IP67) according to EN 60529 |
| Ambient temperature | -10 ° to +50 °C |
| Allowable humidity | Max. 90 % relative humidity, non condensing |
| Housing material | PP-GF |
| Actuating angle | Max. 355°, set to 90° |
| Nominal torque EA25 | 10 (25) Nm |
| Nominal torque EA45 | 20 (45) Nm |
| Nominal torque EA120 | 60 (120) Nm |
| Nominal torque EA250 | 100 (250) Nm |
| Weight EA25 | 2,1 kg |
| Flange fitting EA250 | F07 |
The actuators are available with 100–230 V AC or 24 V AC/DC nominal voltage at 50/60 Hz, with a tolerance of ± 15%.
The protection class is IP 65 (IP67) according to EN 60529, with IP67 applying when cable glands and vertical installation are used.
The actuating angle is max. 355° and the actuator is set to 90° at delivery.
Yes, all accessories can be retrofitted and they work with both the 100–230 V and the 24 V versions.