Multimeter user manual, introducing the features and functions of the multimeter.
This manual covers the IDEAL Vol-Con Voltage/Continuity Tester (models 61-080 and 61-076) and the Vol-Test Voltage Tester (models 61-067 and 61-065). It describes safety precautions, features such as vibration mode with indicator movement, auto-switching voltage/continuity technology, low impedance and replaceable test leads, and how to measure AC/DC voltage and test continuity.
It also explains applications including locating blown fuses, finding the grounded side of a line, checking continuity of cords, motors and appliances, and locating excessive leakage to ground, along with battery replacement, accessories, maintenance, specifications and warranty information.
| AC voltage ranges | 120V, 240V, 480V, 600V AC |
|---|---|
| DC voltage ranges | 120V, 240V, 600V DC |
| Voltage indication | 5-600V AC/DC (61-076, 61-080); 100-600V AC/DC (61-065, 61-067) |
| Continuity | LED lights at <500kΩ, response time 100ms |
| Frequency | Operates at 25-60 Hz |
| Overload protection | 1000VDC/750VAC rms |
| Operating environment | 32°F to 122°F (0 to 50°C), <70% humidity |
| Storage temperature | -4°F to 140°F (-20 to 60°C), <80% humidity |
| Batteries | Models 61-080 & 61-076 only: (4) 1.5V (61-201, IEC LR44) |
| Battery life | 200 hours typical |
| Dimensions | 7.2"H x 2.4"W x 1.5"D (183H x 61W x 38D mm) |
| Weight | 8.0 oz (227g) |
| Safety rating | UL 61010B-1, CAT III-600V, double insulation |
The 61-076 and 61-080 indicate 5-600V AC/DC, while the 61-065 and 61-067 indicate 100-600V AC/DC.
Connect the tester to a de-energized circuit; if the circuit has less than 500kΩ, the continuity LED lights.
Models 61-080 and 61-076 use four 1.5V batteries (61-201, IEC LR44), with a typical life of 200 hours.
Remove the test leads, pry the two battery caps from the bottom of the case with a screwdriver, replace the batteries and snap the caps back in place.