About this manual

This document is reliability data for the TDK-Lambda RWS600B power supply. It reports calculated MTBF values, component derating, and main component temperature rise.

It also covers thermal shock testing conditions and results, plus fan life expectancy data. This manual is written in Japanese.

What's inside

  • MTBF Calculated Values
  • Component Derating
  • Main Components Temperature Rise AT List
  • Electrolytic Capacitor Lifetime
  • Abnormal Test
  • Vibration Test
  • Noise Simulate Test
  • Thermal Shock Test
  • Fan Life Expectancy

Specifications

MTBF at 25 C ambient2,157,340 hours
MTBF at 40 C ambient1,173,882 hours
Part-count MTBF154,279 hours
Thermal shock test cycles100 cycles
Fan model2410SB-04W-B60
Output derating at 100 VAC92%
Full-load output currents at 110-265 VAC100 A, 50 A, 25 A, 12.5 A

Frequently asked questions

What is the calculated MTBF at 25 C ambient?

The parts-stress MTBF at 25 C ambient is 2,157,340 hours.

What fan is used in the RWS600B?

The fan is model 2410SB-04W-B60 from Minebea Moter Manufacturing Corporation.

How many thermal shock cycles were applied?

The thermal shock test used 100 cycles.

What is the output derating at 100 VAC?

At 100 VAC the output is derated to 92%, with full-load currents of 92 A, 46 A, 23 A, and 11.5 A for 5 V, 12 V, 24 V, and 48 V.