B&C TU7685 Sludge Concentration (SS) Monitor Installation and Operation Manual

The TU7685 is a microprocessor-based sludge concentration (SS) controller that uses an infrared light scattering measurement method. The sensor light source uses an LED diode to emit light, which has the advantages of accurate measurement, stable performance and long service life.


B&C TU7685 Sludge Concentration (SS) Monitor Installation and Operation Manual - cover page
Brand
B&C
Category
Monitoring Equipment
Document type
User Manual
Language
Chinese
Pages
10
File format
PDF
File size
198 KB
Published
07 November, 2023
Updated
07 November, 2023
Model
TU7685
MD5 checksum
7CB39969B78ECFB5266D246269E1CAE7

About this manual

This installation and operation manual covers the B&C TU7685 sludge concentration (SS) monitor together with the TU8182 immersion sensor. The document is published by Shanghai Anbi Environmental Protection Equipment Co., Ltd. (www.absh.cn). It describes the measuring principle, the measuring ranges, the panel-mount dimensions, the sensor installation, the terminal wiring, and the configuration settings that are made with the MODE, CAL, ENT and arrow keys.

The TU7685 is a microprocessor-based instrument that uses an infrared light scattering method; the sensor light source is an LED diode. It offers two banks and four ranges (0-9, 0-999, 0-99 and 0-9999 mg/l) selectable in units of NTU, mg/l or ppm, a 0-20 mA or 4-20 mA analog output, two SPDT control relays, an SPST alarm relay and an SPST cleaning relay. The manual walks through the configuration menu step by step and explains the main displays and the AUTO/MAN operating modes. This manual is written in Chinese.

What's inside

  • Introduction
  • Standard package contents
  • Dimensions and panel cutout
  • Measuring principle
  • Measuring ranges
  • Installation of the monitor and sensor
  • Electrical connections
  • Configuration menu settings
  • Main displays and AUTO/MAN mode

Specifications

Measuring principleInfrared light scattering method with LED light source
Measuring rangesTwo banks, four ranges: 0-9, 0-999, 0-99 and 0-9999 mg/l
Measuring unitsNTU, mg/l, ppm
Power supply220 V / 50 Hz
Monitor dimensions96 × 96 × 155 mm
Panel cutout91.5 × 91.5 mm
Analog output0-20 mA or 4-20 mA
Response time, large signal change5-220 s, factory setting 40 s
Control relaysTwo SPDT control relays
Sensor cable7.5 m, 7-core cable supplied with the TU8182 sensor

Frequently asked questions

How does the TU7685 measure sludge concentration?

It uses an infrared light scattering method; the sensor contains an LED infrared light source, a light signal detector, a lens condition detector and a preamplifier.

What measuring ranges and units are available?

There are two banks with four ranges: 0-9 and 0-999 mg/l, or 0-99 and 0-9999 mg/l, with units selectable as NTU, mg/l or ppm.

What power supply does the TU7685 require?

The monitor is powered from 220 V / 50 Hz through the numbered terminals on the back (1 neutral, 3 live, 4 ground).

How is the TU8182 sensor connected to the monitor?

Its 7-core cable is wired to the matching terminal numbers on the back of the TU7685; if the cable must be extended, a highly insulated junction box should be used rather than cutting the cable.

Download PDF (198 KB)

More B&C Manuals


View all B&C manuals →